Dosimetry comparison between TG-43 and Monte Carlo calculations using the Freiburg flap for skin high-dose-rate brachytherapy

2012

Abstract Purpose The purpose of this work was to evaluate whether the delivered dose to the skin surface and at the prescription depth when using a Freiburg flap applicator is in agreement with the one predicted by the treatment planning system (TPS) using the TG-43 dose-calculation formalism. Methods and Materials Monte Carlo (MC) simulations and radiochromic film measurements have been performed to obtain dose distributions with the source located at the center of one of the spheres and between two spheres. Primary and scatter dose contributions were evaluated to understand the role played by the scatter component. A standard treatment plan was generated using MC- and TG-43-based TPS appl…

Skin Neoplasmsmedicine.medical_treatmentBrachytherapyBrachytherapyMonte Carlo methodSensitivity and SpecificitySkin surfacemedicineHumansDosimetryRadiology Nuclear Medicine and imagingRadiochromic filmRadiation treatment planningSkinbusiness.industryRadiotherapy Planning Computer-AssistedReproducibility of ResultsRadiotherapy DosageEquipment DesignHigh-Dose Rate BrachytherapyComputational physicsEquipment Failure AnalysisOncologySPHERESNuclear medicinebusinessMonte Carlo MethodSoftwareBrachytherapy
researchProduct

Monte Carlo calculation of dose rate distributions around 192Ir wires.

1997

Monte Carlo calculations of absolute dose rate in liquid water are presented in the form of away-along tables for 1 and 5 cm 192 Ir wires of 0.3 mm diameter. Simulated absolute dose rate values can be used as benchmark data to verify the calculation results of treatment planning systems or directly as input data for treatment planning. Best fit value of attenuation coefficient suitable for use in Sievert-integrals-type calculations has been derived based on Monte Carlo calculation results. For the treatment planning systems that are based on TG43 formalism we have also calculated the required dosimetry parameters.

PhysicsLiquid waterRadiotherapy Planning Computer-AssistedMonte Carlo methodBrachytherapyBiophysicsRadiotherapy DosageGeneral MedicineReference StandardsIridium RadioisotopesBiophysical PhenomenaComputational physicsEvaluation Studies as TopicAttenuation coefficientNeoplasmsDynamic Monte Carlo methodDosimetryHumansComputer SimulationStatistical physicsBenchmark dataDose rateMonte Carlo MethodMedical physics
researchProduct

Magnetic resonance imaging of dysraphic myelodysplasia

1988

The spinal cord in 56 children and adolescents was examined by magnetic resonance imaging (MRI) many years after neonatal surgery on a meningomyelocele (average age 12 years). In a high percentage of cases, the diagnosis "tethered cord" was made. Associated anomalies were found with a frequency of 21%. Typical findings are presented and the impact of these results on therapy planning is discussed.

Malemedicine.medical_specialtyMeningomyeloceleTissue AdhesionsTherapy planningPostoperative ComplicationsmedicineHumansNeural Tube DefectsChildTethered Cordmedicine.diagnostic_testbusiness.industryFollow up studiesMagnetic resonance imagingGeneral MedicineSpinal cordMagnetic Resonance ImagingSurgeryNeonatal surgerymedicine.anatomical_structureEl NiñoPediatrics Perinatology and Child HealthFemaleNeurology (clinical)NeurosurgeryRadiologybusinessFollow-Up StudiesChild's Nervous System
researchProduct

Exclusive MRI-based tandem and colpostats reconstruction in gynaecological brachytherapy treatment planning

2008

Purpose: According to the GYN GEC-ESTRO Recommendations, MRI is needed with the modality of T2 weighted. CT-MR compatible tandem Plus colpostats (T/C) (Nucletron) is widely used in cervical brachytherapy. The major challenge of MRI is the lack of dummy catheters. Therefore, an additional imaging modality is usually required. One disadvantage of sliced-based reconstruction is that resolution in longitudinal directions can be affected by the slice thickness. The aim of this study is to present a modified T/C applicator in which the catheter visibility is significantly improved. Methods and materials: A modification to the existing T/C applicator has been made available, increasing the cathete…

medicine.medical_specialtyGenital Neoplasms Femalebusiness.industryRadiotherapy Planning Computer-AssistedSlice thicknessmedicine.medical_treatmentBrachytherapyBrachytherapyRadiotherapy DosageHematologyMagnetic Resonance ImagingCatheterizationCatheterOncologymedicineHumansDosimetryFemaleRadiology Nuclear Medicine and imagingRadiologyNuclear medicinebusinessRadiation treatment planningT2 weighted
researchProduct

Interobserver variability in rectum contouring in high-dose-rate brachytherapy for prostate cancer: A multi-institutional prospective analysis

2017

PURPOSE: The aim of this study was to evaluate the interobserver variability (KW) of rectum contouring, and its dosimetric consequences, for high-dose-rate brachytherapy in patients with prostate cancer across multiple institutions. METHODS AND MATERIALS: Five radiation oncologists contoured rectums in 10 patients on transperineal ultrasound image sets after establishing a delineation consensus. The D-0.1cc, D-1cc, and D-2cc rectum volume parameters were determined. The mean, standard deviation, and range of each dose-volume histogram parameter were evaluated for each patient. The JOY was determined using the coefficient of variation, and the dosimetric impacts on the total dose were analyz…

MaleOrgans at Riskmedicine.medical_specialtyCoefficient of variationmedicine.medical_treatmentBrachytherapyBrachytherapyRectumRadiation DosageStandard deviationEndosonography030218 nuclear medicine & medical imaging03 medical and health sciencesProstate cancer0302 clinical medicineHumansMedicineRadiology Nuclear Medicine and imagingProspective StudiesObserver VariationContouringProstate cancerbusiness.industryEquivalent doseRadiotherapy Planning Computer-AssistedRectumProstatic NeoplasmsRadiotherapy DosageOrgan Sizemedicine.diseaseHigh-Dose Rate Brachytherapymedicine.anatomical_structureOncologyContouringHigh-dose-rate brachytherapy030220 oncology & carcinogenesisRadiologyInterobserver variabilitybusinessNuclear medicineBrachytherapy
researchProduct

On the use of the absorbed depth-dose measurements in the beam calibration of a surface electronic high-dose-rate brachytherapy unit, a Monte Carlo-b…

2019

PURPOSE To evaluate the use of the absorbed depth-dose as a surrogate of the half-value layer in the calibration of a high-dose-rate electronic brachytherapy (eBT) equipment. The effect of the manufacturing tolerances and the absorbed depth-dose measurement uncertainties in the calibration process are also addressed. METHODS The eBT system Esteya® (Elekta Brachytherapy, Veenendaal, The Netherlands) has been chosen as a proof-of-concept to illustrate the feasibility of the proposed method, using its 10 mm diameter applicator. Two calibration protocols recommended by the AAPM (TG-61) and the IAEA (TRS-398) for low-energy photon beams were evaluated. The required Monte Carlo (MC) simulations w…

Surface (mathematics)Materials scienceBackscattermedicine.medical_treatmentBrachytherapyMonte Carlo methodBrachytherapyPermeability030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinemedicineCalibrationDosimetryRadiometryAirRadiotherapy Planning Computer-AssistedX-RaysUncertaintyReproducibility of ResultsWaterRadiotherapy DosageGeneral MedicineEquipment DesignHigh-Dose Rate BrachytherapyComputational physics030220 oncology & carcinogenesisCalibrationMonte Carlo MethodBeam (structure)Medical physicsReferences
researchProduct

A fully automatic approach for multimodal PET and MR image segmentation in gamma knife treatment planning

2017

The aim of this study is to combine Biological Target Volume (BTV) segmentation and Gross Target Volume (GTV) segmentation in stereotactic neurosurgery.Our goal is to enhance Clinical Target Volume (CTV) definition, including metabolic and morphologic information, for treatment planning and patient follow-up.We propose a fully automatic approach for multimodal PET and MR image segmentation. This method is based on the Random Walker (RW) and Fuzzy C-Means clustering (FCM) algorithms. A total of 19 brain metastatic tumors, undergone stereotactic neuro-radiosurgery, were retrospectively analyzed. A framework for the evaluation of multimodal PET/MRI segmentation is presented, considering volume…

Radiotherapy PlanningBrain tumorHealth Informatics02 engineering and technologyFuzzy C-means clusteringRadiosurgeryBrain tumorsMultimodal ImagingING-INF/05 - SISTEMI DI ELABORAZIONE DELLE INFORMAZIONI030218 nuclear medicine & medical imaging03 medical and health sciencesComputer-Assisted0302 clinical medicineRandom walker algorithm0202 electrical engineering electronic engineering information engineeringHumansMedicineSegmentationComputer visionRadiation treatment planningCluster analysisImage resolutionPET/MR imagingModality (human–computer interaction)Brain Neoplasmsbusiness.industryRadiotherapy Planning Computer-AssistedINF/01 - INFORMATICAMultimodal therapymedicine.diseaseRandom Walker algorithmMagnetic Resonance ImagingComputer Science ApplicationsBrain tumorGamma knife treatmentPositron-Emission Tomography020201 artificial intelligence & image processingMultimodal image segmentationBrain tumors; Fuzzy C-means clustering; Gamma knife treatments; Multimodal image segmentation; PET/MR imaging; Random Walker algorithm; Brain Neoplasms; Humans; Radiosurgery; Magnetic Resonance Imaging; Multimodal Imaging; Positron-Emission Tomography; Radiotherapy Planning Computer-AssistedArtificial intelligencebusinessGamma knife treatmentsSoftware
researchProduct

Dosimetric characteristics of backscattered electrons in lead.

2000

In electron beam therapy, tissue overdose due to electrons backscattered from lead has been profusely studied. To quantify this dose enhancement effect, an electron backscatter factor (EBF) was defined as the ratio of dose at the tissue-inhomogeneity interface with and without the scatterer present. The dependence of the EBF on energy at the scatterer surface is not well known for energies lower than 3 MeV which is the most frequent clinical situation. In this work, we have done Monte Carlo calculations with the GEANT code to study EBF in lead at this energy range. The applicability of this code and the developed procedure for dose estimation has been experimentally verified. The dependence…

PhysicsRange (particle radiation)Radiological and Ultrasound Technologybusiness.industryRadiotherapy Planning Computer-AssistedPhysics::Medical PhysicsMonte Carlo methodDose-Response Relationship RadiationElectronsElectronRadiationComputational physicsOpticsLeadCathode rayElectron Beam TherapyDosimetryRadiology Nuclear Medicine and imagingComputer SimulationbusinessRadiometryMonte Carlo MethodBeam (structure)AlgorithmsSoftwarePhysics in medicine and biology
researchProduct

Intensity-modulated extended-field chemoradiation plus simultaneous integrated boost in the pre-operative treatment of locally advanced cervical canc…

2015

Objective: To investigate the feasibility and determine the recommended pre-operative intensity-modulated radiotherapy (IMRT) dose of extended-field chemoradiation along with simultaneous integrated boost (SIB) dose escalation. Methods: A radiation dose of 40Gy over 4 weeks, 2Gy/fraction, was delivered to the tumour and the lymphatic drainage (planning target volume, PTV3), which encompassed a volume larger than standard (common iliac lymphatic area up to its apex, in front of the L3 vertebra), concurrently with chemotherapy (cisplatin and 5-fluorouracil). Radiation dose was escalated to the pelvis (PTV2) and to the macroscopic disease (PTV1) with the SIB-IMRT strategy. Three dose levels we…

Chemoradiotherapy; Dose Fractionation; Feasibility Studies; Female; Humans; Middle Aged; Neoplasm Staging; Preoperative Period; Prospective Studies; Radiotherapy Dosage; Radiotherapy Planning Computer-Assisted; Radiotherapy Intensity-Modulated; Treatment Outcome; Uterine Cervical Neoplasms; Radiology Nuclear Medicine and Imaging; Medicine (all)Uterine Cervical NeoplasmRadiology Nuclear Medicine and Imagingcervical cancermedicine.medical_treatmentUterine Cervical NeoplasmsMedicineHumansProspective StudiesProspective cohort studyDose FractionationSettore MED/36 - DIAGNOSTICA PER IMMAGINI E RADIOTERAPIANeoplasm StagingCervical cancerCisplatinChemotherapyFull Paperbusiness.industryMedicine (all)Radiotherapy Planning Computer-AssistedDose fractionationRadiotherapy DosageGeneral MedicineChemoradiotherapyMiddle Agedmedicine.diseaseRadiation therapyFeasibility StudieProspective StudieLymphatic systemTreatment OutcomePreoperative PeriodFeasibility StudiesFemaleDose Fractionation RadiationRadiotherapy Intensity-ModulatedbusinessNuclear medicineChemoradiotherapymedicine.drugHumanThe British journal of radiology
researchProduct

Verification of a commercial implementation of the Macro-Monte-Carlo electron dose calculation algorithm using the virtual accelerator approach.

2009

Abstract In this work, the accuracy of the implementation of the Macro Monte Carlo electron dose calculation algorithm into the radiation therapy treatment planning system Eclipse is evaluated. This implementation – called eMC – uses a particle source based on the Rotterdam Initial Phase-Space model. A three-dimensional comparison of eMC calculated dose to dose distributions resulting from full treatment head simulations with the Monte Carlo code package EGSnrc is performed using the ‘virtual accelerator’ approach. Calculated dose distributions are compared for a homogeneous tissue equivalent phantom and a water phantom with air and bone inhomogeneities. The performance of the eMC algorithm…

medicine.medical_specialtyMonte Carlo methodBiophysicsElectronsImaging phantomUser-Computer InterfaceElectron dosemedicineHumansRadiology Nuclear Medicine and imagingMedical physicsMacroLungEclipsePhysicsRadiological and Ultrasound TechnologyPhantoms ImagingRadiotherapy Planning Computer-AssistedCalculation algorithmWaterRadiotherapy DosageSpineComputational physicsRadiographyTracheaTissue equivalentHomogeneousHeadMonte Carlo MethodAlgorithmsZeitschrift fur medizinische Physik